MODELLING AND CONTROL OF ARTERIAL OXYGEN SATURATION IN NEONATAL INFANTS
Electrical
Abstract
This paper presents design a closed loop oxygen controller for the supplement oxygen to the newborn infant. The most problem for premature infants is respiratory distress syndrome (RDS), also called neonatal respiratory distress syndrome, or respiratory distress syndrome of newborn. Due to Respiratory Distress Syndrome, the infant requires mechanical to increase the inspired oxygen. We must keep the range of the Arterial Oxygen Saturation (